Magner 150: Resolving 'Double Bill' Detection Errors

Troubleshooting Magner 150 bill counter flagging bills as 'Double'. Diagnostics, cleaning, and maintenance for separation roller issues.

Frequently Asked Questions

What cleaning solutions are safe to use on the Magner 150's rollers and sensors?

Use a specialized rubber roller cleaner or isopropyl alcohol (90% or higher) on a lint-free cloth. Ensure the cloth is only slightly damp to avoid liquid damage.

How often should the separation rollers be replaced?

Separation rollers should be inspected every 6 months and replaced every 12-24 months, depending on usage and bill volume. Look for signs of wear, cracking, or hardening.

What are the voltage tolerance specifications for the 24V DC power supply input?

The voltage tolerance is typically +/- 5%, meaning the input voltage should be between 22.8V and 25.2V DC.